Product Info > Electronics Device Business Unit > Connector Division > By Application

|
SS-type Inter-Connector consists of alternate layers of conductive and insulating silicone rubber and of rubber insulators with less stiffness, which are fitted on both sides. This type is suitable for small- or middle-sized displays.
While SS type has translucent supportive solid rubber on the both sides, SG type has pink sponge rubber.
|
 |
 |
Outline Dimensions
Dimensions and Tolerances
| Item |
Unit |
SS Type |
|
| Pitch (P) |
mm |
0.10±0.04, 0.18±0.05, 0.25±0.05 |
|
|
| Length (L) |
mm |
2.0~20.0±0.15, 90.1~150.0±0.6, 200.1~275.0±1.0, 20.1~90.0±0.65%,
150.1~200.0±0.8 |
|
|
| Height (H)* |
mm |
1.0~5.0±0.1, 5.1~20.0+0.15/-0.1 |
|
|
| Width (Standard) (W) |
mm |
1.0~2.3±0.1, 2.4~5.0±0.15 |
|
|
Width of Conductive Layer (Z) |
mm |
0.3±0.05(standard), 0.6±0.05(secondary standard) |
* H W/2
SS-N type, which has non-sticky sides is available on request.
Shin-Etsu Inter-Connector has been registered in European Community, TM No. 000299016, and in the United States of America, TM No. 2078941.
Basic Properties
| Item |
Component |
Unit |
SS Type |
|
| Specific Gravity |
Insulator Conductor Edge insulation part |
|
1.15 1.25 1.10 |
|
|
| Shore Hardness A |
Insulator Conductor Edge insulation part |
ISO7619 (TYPE A) |
65~73 63~67 20~25 |
|
|
| Compression Set |
* |
% |
12~18 |
|
|
| Volume Resistivity |
Insulator Conductor Edge insulation part |
, cm |
1×1014 3~6 8×1013 |
|
|
| Dielectric Breakdown Voltage |
Insulator Edge insulation part |
kV/mm |
23~27 23~27 |
|
|
| Insulation Resistance (500V DC) |
* |
M |
1×10³ |
|
|
| Operating Temperature Range |
|
°C |
-25~85 |
* The test is carried out with Shin-Etsu's own method.
Compression Curves
Note
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
The quality of the connector, which has been already assembled, is out of guarantee.
Please make sure to see about the purpose/conditions of use and practice your own test.
Industrial ownership like patent doesn't guarantee the usage of the connector.
| back |
|
 |